Your browser doesn't support javascript.
loading
Stents biodegradables y stents con estrutura bioabsorbible para enfermedad coronaria / Biodegradable stents and bioresorbable scaffold stents in coronary artery disease / Stents biodegradáveis e stents com estrutura bioabsorvível para doença coronária
Buenos Aires; IECS; jul. 2014.
Non-conventional in Spanish | BRISA/RedTESA, BRISA/RedTESA | ID: biblio-996562
Responsible library: BR1.1
RESUMEN

INTRODUCCIÓN:

Se denomina enfermedad arterial coronaria (EAC) al estrechamiento de la luz vascular debida al depósito de placas ateroescleróticas. En la Argentina, en 2010, 30,5% de las muertes se debieron a causas cardiovasculares, siendo las isquémicas las más importantes. Ante la falla del tratamiento médico las opciones son el bypass coronario o la angioplastia transluminal percutánea, usualmente con la inserción de stents. Los primeros stents desarrollados fueron los metálicos (SM). Posteriormente, aparecieron los stents liberadores de drogas (SLD), recubiertos de polímero duradero impregnado en drogas anti-proliferativas lo que se asoció con una reducción de la re estenosis arterial en algunos grupos de pacientes. Recientemente aparecieron los stents con polímero biodegradable (SBD, en inglés Biodegradable polymer stents) y los stents con estructura bioabsorbible (SBA, en inglés Bioresorbable stents, bioresorbable scaffold stents) con la ventaja potencial de presentar menor trombosis intra-stent y menor necesidad de doble antiagregación. TECNOLOGÍA Los SBD incorporan a la plataforma de metal un polímero biodegradable impregnado con drogas anti-proliferativas. Este polímero se degrada lentamente, lo cual minimiza el riesgo asociado con la permanencia prolongada del polímero en la pared arterial, aunque la plataforma de metal permanece en el vaso. En el caso de los SBA, la plataforma es reemplazada por una que se absorbe en el tiempo.

OBJETIVO:

Evaluar la evidencia disponible acerca de la eficacia, seguridad y aspectos relacionados a las políticas de cobertura del uso de SBD y SBA en pacientes con enfermedad arterial coronaria.

MÉTODOS:

Se realizó una búsqueda en las principales bases de datos bibliográficas (incluyendo Medline, Cochrane y CRD), en buscadores genéricos de Internet, agencias de evaluación de tecnologías sanitarias y financiadores de salud. Se priorizó la inclusión de revisiones sistemáticas, ensayos clínicos controlados aleatorizados (ECAs), evaluaciones de tecnologías sanitarias (ETS) y económicas, guías de práctica clínica y políticas de cobertura de otros sistemas de salud cuando estaban disponibles.

RESULTADOS:

Se reportan los resultados principales. Se incluyeron dos meta-análisis, un ECA posterior, y dos ETS.

CONCLUSIONES:

Existe al momento escasa evidencia comparativa directa entre SBD y SM que no muestra diferencias clínicamente relevantes en eventos cardiacos mayores, para el tratamiento de la EAC. Existe evidencia de alta calidad metodológica que no mostró diferencias clínicamente significativas entre los SBD y SLD con polímero permanente en los pacientes que tienen indicación de SLD, en desenlaces duros como incidencia de IAM y mortalidad, en el corto plazo; siendo inconsistentes los resultados respecto al riesgo de trombosis del stent. Por otro lado, no existe evidencia para los SBA en comparación con los SBD y SM. Las políticas de cobertura identificadas consideran a los SBD y SBA aún en etapa experimental. Sin embargo, ambos tienen ventajas potenciales que son estudiadas en varios ECAs en curso.
ABSTRACT

INTRODUCTION:

Coronary artery disease (CAD) is the narrowing of the vascular lumen due to atherosclerotic plaque buildup. In Argentina, 30.5% of deaths were due to cardiovascular causes in 2010, being the ischemic causes the most important ones. When medical treatment fails, coronary bypass or percutaneous transluminal angioplasty, usually with stent placement, become the options. The first stents developed were the bare-metal stents (BMS). Later, drug-eluting stents (DES), coated with a long-lasting polymer and soaked in anti-proliferative drugs came up; these were associated with a decrease in arterial restenosis in some groups of patients. Recently, biodegradable polymer stents (BDS) and the bioresorbable scaffold stents, bioresorbable scaffold stents (BRS) came into scene with the potential advantage of presenting less intrastent thrombosis and a lower need for double anti-aggregation therapy. TECHNOLOGY BDSs incorporate a biodegradable polymer soaked in anti-proliferative drugs to the metal platform. This polymer slowly degrades minimizing the risk associated with prolonged permanence of the polymer on the arterial wall, even though the metal platform remains in the vessel. In the case of BRSs, the platform is replaced with one that is absorbed with time.

PURPOSE:

To assess the available evidence on the efficacy, safety and coverage related issues regarding the use of BDS and BRS in patients with coronary artery disease.

METHODS:

A bibliographic search was carried out on the main databases (such as MEDLINE, Cochrane and CRD), in general Internet engines, in health technology assessment agencies and health sponsors. Priority was given to the inclusion of systematic reviews; controlled, randomized clinical trials (RCTs); health technology assessments (HTAs) and economic evaluations, clinical practice

RESULTS:

The main results are reported below.guidelines and coverage policies of other health systems, when available. Two meta-analyses, one RCT of later date and two HTAs were included.

CONCLUSIONS:

At present, there is poor direct comparative evidence between BDS and MS not showing clinically relevant differences in major cardiac events, for the treatment of CAD. There is evidence of high methodological quality not showing clinically significant differences between BDS and permanent polymer-coated DES in patients with indication for DES, in difficult outcomes such as the incidence of AMI and mortality, at short term, being the results inconsistent in terms of risk of stent thrombosis. On the other hand, there is not evidence favoring BRS versus BDS and MS. The identified coverage policies consider that BDS and BRS are still at experimental stage. However, both of them have potential advantages that are being studied in several ongoing RCTs.
RESUMO

INTRODUÇÃO:

Denomina-se doença arterial coronária (DAC) ao estreitamento da luz vascular devido ao depósito de placas ateroscleróticas. Na Argentina, em 2010, 30,5% das mortes foram por causas cardiovasculares, sendo as isquêmicas as mais importantes. Ante a falha do tratamento médico as opções são o bypass coronário ou a angioplastia transluminal percutânea, usualmente com a inserção de stents. Os primeiros stents desenvolvidos foram os metálicos (SM). Posteriormente, apareceram os stents liberadores de drogas (SLD), recobertos de polímero duradouro impregnado em drogas anti-proliferativas, o que se associou com uma redução da re estenose arterial em alguns grupos de pacientes. Recentemente apareceram os stents co, polímero biodegradável (SBD, em inglês Biodegradable polymer stents) e os stents com estrutura bioabsorvível (SBA, em inglês Bioresorbable stents, bioresorbable scaffold stents) com a vantagem potencial de apresentar menor trombose intra-stent e menor necessidade de duplo anti agregante. TECNOLOGIA Los SBD incorporam a plataforma de metal um polímero biodegradável impregnado com drogas anti-proliferativas. Este polímero se degrada lentamente, minimizando o risco associado com a permanência prolongada do polímero na parede arterial, ainda que a plataforma de metal permaneça no vaso. No caso dos SBA, a plataforma é substituída por uma que se absorve ao longo do tempo.

OBJETIVO:

Avaliar a evidencia disponível sobre a eficácia, segurança e aspectos relacionados às políticas de cobertura do uso de SBD e SBA em pacientes com doença arterial coronária.

MÉTODOS:

Realizou-se uma busca nas principais bases de dados bibliográficos (incluindo Medline, Cochrane e CRD), em buscadores genéricos de Internet, agências de avaliação de tecnologias sanitárias e financiadores de saúde. Priorizou-se a inclusão de revisões sistemáticas (RS), ensaios clínicos controlados aleatorizados (ECAs), avaliações de tecnologias em saúde (ATS) e econômicas, guias de práticas clínica (GPC) e políticas de cobertura de outros sistemas de saúde quando estavam disponíveis.

RESULTADOS:

Reportam-se os principais resultados. Incluíram-se duas meta-análises, um ECA posterior, e duas ATS.

CONCLUSÕES:

Existe atualmente escassa evidência comparativa direta entre SBD y SM que não mostra diferenças clinicamente relevantes em eventos cardíacos maiores, para o tratamento da DAC. Existe evidencia de alta qualidade metodológica que não mostrou diferenças clinicamente significativas entre os SBD e SLD com polímero permanente nos pacientes que têm indicação de SLD, em desfechos duros como incidência de IAM e mortalidade em curto prazo; sendo inconsistentes os resultados referentes ao risco de trombose do stent. Por outro lado, não existe evidência para os SBA comparados aos SBD e SM. As políticas de cobertura identificadas consideram aos SBD e SBA ainda em etapa experimental. Porém, ambos têm vantagens potenciais que são estudadas em vários ECAs em curso.
Subject(s)
Full text: Available Collection: Tematic databases Health context: 6_ODS3_enfermedades_notrasmisibles Health subject: 6_cardiovascular_diseases / 6_ischemic_heart_disease Database: BRISA/RedTESA Main topic: Stents / Coronary Disease / Absorbable Implants Type of study: Controlled clinical trial / Evaluation study / Practice guideline / Health technology assessment Demographic groups: Humans Language: Spanish Year: 2014 Document type: Non-conventional

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Collection: Tematic databases Health context: 6_ODS3_enfermedades_notrasmisibles Health subject: 6_cardiovascular_diseases / 6_ischemic_heart_disease Database: BRISA/RedTESA Main topic: Stents / Coronary Disease / Absorbable Implants Type of study: Controlled clinical trial / Evaluation study / Practice guideline / Health technology assessment Demographic groups: Humans Language: Spanish Year: 2014 Document type: Non-conventional