Your browser doesn't support javascript.
loading
PET/PET-TC para cáncer de páncreas y vía biliar / PET/PET CT for pancreatic and bile duct cancer / PET/PET-TC para câncer de pâncreas y via biliar
Buenos Aires; IECS; mayo 2014.
Non-conventional in Spanish | BRISA/RedTESA | ID: biblio-996263
Responsible library: BR1.1
RESUMEN

INTRODUCCIÓN:

Se estima que en Argentina se diagnostican 4.000 casos de cáncer de páncreas por año. Los cánceres de vía biliar son menos frecuentes. Estos cánceres tienen sobrevidas menores al 5% a los 5 años. El diagnóstico y la estadificación se basan en la historia clínica, análisis de laboratorio y estudios por imágenes, incluyendo ecografía, tomografía computada (TC) y resonancia magnética nuclear (RMN). La confirmación diagnóstica es por histopatología. Se postula la tomografía por emisión de positrones con tomografía computada (PET-TC) como complemento o alternativa a la TC y la RMN para el cáncer de páncreas y de la vía biliar. TECNOLOGÍA La PET-TC es una técnica de imagen funcional y anatómica combinada que utiliza la inyección en el paciente de radiofármacos marcados, como el 18-FDG, seguida por tomografía axial, lo que brinda el alto contraste metabólico del PET, junto con la alta resolución espacial de la TC.

OBJETIVO:

Evaluar la evidencia disponible acerca de la eficacia, utilidad diagnóstica y pronostica, seguridad y aspectos relacionados a las políticas de cobertura del uso de PET y PET-TC en cáncer de páncreas y vía biliar.

MÉTODOS:

Se realizó una búsqueda en las principales bases de datos bibliográficas (incluyendo Medline, Cochrane y CRD), en buscadores genéricos de Internet, agencias de evaluación de tecnologías sanitarias y financiadores de salud. Se priorizó la inclusión de revisiones sistemáticas (RS), ensayos clínicos controlados aleatorizados, evaluaciones de tecnologías sanitarias y económicas (ETS), guías de práctica clínica (GPC) y políticas de cobertura de otros sistemas de salud. Se incluyeron estudios que tenían como patrón de referencia la histopatología o por lo menos 6 meses de seguimiento clínico.

RESULTADOS:

Se incluyeron cuatro RS, ocho GPC, un documento de ETS, seis series de casos y la cobertura de siete financiadores de salud.

CONCLUSIONES:

La calidad de la evidencia sobre el uso de PET/PET-TC en cáncer de páncreas es alta, y proviene principalmente de revisiones sistemáticas cuyos estudios permiten establecer valores elevados de sensibilidad y especificidad, pero no superioridad en cuanto a métodos convencionales (ecografía, TC y RMN). Escasa evidencia de baja calidad metodológica mostró superioridad de la técnica para la detección de metástasis a distancia en cáncer de vía biliar, aunque no para diagnóstico y estadificación. Las guías y los financiadores coinciden en que PET/PET-TC no deben ser utilizadas de rutina en cáncer de páncreas o vía biliar.
ABSTRACT

INTRODUCTION:

It is estimated that 4,000 cases of pancreatic cancer are diagnosed in Argentina every year. Bile duct cancers are less common. These cancers have a survival rate of less than 5% at 5 years. Diagnosis and staging are based on the clinical record, laboratory testing and imaging studies, including ultrasound, computed tomography (CT) and magnetic resonance imaging (MRI). Diagnostic confirmation is made by histopathology. Positron emission tomography with computed tomography (PET-CT) has been proposed as a supplement or alternative to CT scan and MRI for pancreas and bile duct cancer. TECHNOLOGY PET/CT is a combined functional and anatomic imaging technique which uses radiotracer injections to the patient, such as 18-FDG, followed by computed tomography, thus resulting in PET's high metabolic contrast, together with CT's high spatial resolution.

PURPOSE:

To assess the available evidence on the efficacy, diagnostic and prognostic usefulness, safety and coverage policy related aspects for the use of PET and PET/CT in patients diagnosed with pancreas and bile duct cancers.

METHODS:

A bibliographic search was carried out on the main databases (such as MEDLINE, Cochrane and CRD), in general Internet engines, in health technology assessment agencies and health sponsors. Priority was given to the inclusion of systematic reviews (SRs); controlled, randomized clinical trials (RCTs); health technology assessments (HTAs) and economic evaluations (EEs); clinical practice guidelines (CPGs) and coverage policies of other health systems. Studies with histopathology as the reference standard or less than 6 months of clinical follow-up were included.

RESULTS:

Four SRs, eight CPGs, one HTA document, six case series and coverage from seven health sponsors were included.

CONCLUSIONS:

The quality of the evidence found on the use of PET/PET-CT for pancreatic cancer is high and it mainly comes from systematic reviews whose studies allow setting high sensitivity and specificity values, but there is no superiority over conventional methods (ultrasound, CT scan and MRI). Little evidence of poor methodological quality showed the technique superiority in detecting distant metastasis in bile duct cancer, although not in diagnosing and staging. The guidelines and health sponsors agree that PET/PET-CT should not be routinely used for pancreatic or bile duct cancer.
RESUMO

INTRODUÇÃO:

Estima-se que na Argentina se diagnosticam 4.000 casos de câncer de pâncreas ao ano. Os cânceres da via biliar são menos frequentes. Esses cânceres têm sobrevida menor a 5% aos 5 anos. O diagnóstico e a estadificação se baseiam na história clínica, análise laboratorial e exames de imagens, incluindo ecografia, tomografia computadorizada (TC) e ressonância magnética nuclear (RMN). A confirmação diagnóstica é realizada pela histopatologia. Postula-se a tomografia por emissão de pósitrons com tomografia computadorizada (PET-TC) como complemente ou alternativa a TC e a RMN para o câncer de pâncreas e da va biliar. TECNOLOGIA A PET-TC é uma técnica de imagem funcional e anatômica combinada que utiliza a injeção de radio-fármacos marcados no paciente, como o 18-FDG, seguida por tomografia axial, o que brinda o alto contraste metabólico da PET, junto a alta resolução espacial da TC.

OBJETIVO:

Avaliar a evidência disponível sobre a eficácia, utilidade diagnóstica e prognóstica, segurança e aspectos relacionados às políticas de cobertura do uso da PET e PET-TC no câncer de pâncreas e de via biliar.

MÉTODOS:

Realizou-se uma busca nas principais bases de dados bibliográficos (incluindo Medline, Cochrane e CRD), em buscadores genéricos de Internet, agências de avaliação de tecnologias sanitárias e financiadores de saúde. Priorizou-se a inclusão de revisões sistemáticas (RS), ensaios clínicos controlados aleatorizados (ECAs), avaliações de tecnologias em saúde (ATS) e econômicas, guias de práticas clínica (GPC) e políticas de cobertura de outros sistemas de saúde quando estavam disponíveis. Incluíram-se estudos que tinham como padrão de referência a histopatologia ou pelo menos seis meses de seguimento clínico.

RESULTADOS:

Incluíram-se quatro RS, oito GPC, uma ATS, seis séries de casos e sete políticas de cobertura.

CONCLUSÕES:

A qualidade da evidência sobre o uso da PET/PET-TC em câncer de pâncreas é alta e provêm principalmente de revisões sistemáticas cujos estudos permitem estabelecer valores elevados de sensibilidade e especificidade, mas não superiores em relação aos métodos convencionais (ecografia, TC e RMN). Escassa evidência de baixa qualidade metodológica mostrou superioridade da técnica para a detecção de metástase à distância em câncer de via biliar, ainda que não para diagnóstico e estadificação. Os guias e os financiadores coincidem que a PET/PET-TC não devem ser utilizadas rotineiramente em câncer de pâncreas ou via biliar.
Subject(s)
Full text: Available Collection: Tematic databases Database: BRISA/RedTESA Main topic: Pancreatic Neoplasms / Bile Duct Neoplasms / Positron-Emission Tomography / Positron Emission Tomography Computed Tomography Type of study: Controlled clinical trial / Evaluation study / Practice guideline / Health technology assessment / Prognostic study Demographic groups: Humans Language: Spanish Year: 2014 Document type: Non-conventional

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Collection: Tematic databases Database: BRISA/RedTESA Main topic: Pancreatic Neoplasms / Bile Duct Neoplasms / Positron-Emission Tomography / Positron Emission Tomography Computed Tomography Type of study: Controlled clinical trial / Evaluation study / Practice guideline / Health technology assessment / Prognostic study Demographic groups: Humans Language: Spanish Year: 2014 Document type: Non-conventional